C-MAX
|
| It makes the Cement Concrete quick setting. Final setting). | |
| It expands the surface area of Cement, so that, the Concrete becomes more compact and less porous. | |
| Compactness leads to development of property of water proofing, due to reduction in porosity of concrete. | |
| It is excellent Concrete strengthening and Water Proofing material. | |
| It reduces the water demand of the cement mortar by 30-40%. | |
| As the increased surface area retains more water, this helps in curing the cement and also takes care of deficient curing schedule in water starved areas. |
ADDITION RATES
| Depending on the area of Application, C-Max should be added to Cement in the Ratio of 0.6% to 1.2% of Cement. Most ideal addition rate is 1% of cement. | |
| Mix it with Sand, Cement and chips mixture and use the Mass. |
(a) For Concrete Roofing and Grouting - 1.0% of Cement (Most ideal addition rate)
(b) For Plastering - 1.0% of Cement (Most ideal addition rate)
TYPICAL RESULTS ACHIEVED IN A BIS(ISI) APPROVED CEMENT LABORATORY
| CEMENT SAND RATIO | 1:6 | 1:8 | 1:10 |
| C-MAX Addition | NIL | NIL | NIL |
| Porosity of Cement Blocks after 7 days curing | 35% | 36% | 39% |
| CEMENT SAND RATIO | 1:6 | 1:8 | 1:10 |
| C-MAX Addition | 1.0% of Cement | 1.0% of Cement | 1.0% of Cement |
| Porosity of Cement Blocks after 7 days curing | 3% | 3% | 3.5% |
From the above experiments, it is concluded that, most ideal addition rate for C-Max is 1% of Cement for the water proofing.
| Cement & Sand | 1:8 | 1:6 | Remarks |
| (a) First block | 350kg. cm2 | 350 kg./cm2 | C-Max addition - Nil |
| (b) Second block | 360 kg./cm2 | 360 kg./cm2 | C-Max addition - 0.3% |
| (c) Third block | 400 kg./cm2 | 400 kg./cm2 | C-Max addition - 0.6% |
| (d) Fourth block | 400 kg./cm2 | 400 kg/cm2 | C-Max addition - 1.0% |
| Cement & Sand | 1:8 | 1:6 | Remarks |
| (a) First block | 350kg. cm2 | 350 kg./cm2 | C-max addition - Nil |
| (b) Second block | 360kg./cm2 | 360 kg./cm2 | C-max addition - 0.3% |
| (c) Third block | 400kg./cm2 | 400 kg./cm2 | C-max addition - 0.6% |
| (d) Fourth block | 400kg./cm2 | 400 kg./cm2 | C-max addition - 1.0% |
From the above, it is deduced that, very safely, 15-20% of Cement can be reduced in the plastering job, because they do not involve any risk.for the water proofing.
Contact Us | Disclamair 02
Sreechem Resins Limited
|