GENERAL PRECAUTIONS FOR APPLYING SRL COATINGS

  1. SURFACE PREPARATION : Surface preparation for Metal, Wood and any other objects to be coated, should be prepared meticulously, so that, it is free from oil, grease, salt, chloride moisture, rust etc.

  2. MIXING : All the products of SRL, whether single pack or two pack PU Coatings should be properly mixed before use,

  3. POT LIFE & SHELF LIFE : In our PU coating, the Pot life is indicated on the packaging and shelf life is one years, if stored in a dry enclosed area below the temperature of 35 degree C.

  4. THINNING : Thinning will be done with our Insulthin Universal.

  5. APPLICATION : Application may be done by brushing or spraying and may also be done with airless spray system. Second coat must be done after recommended drying time and as per the instructions given. However, the curing time depends on the temperature. So, as per local condition, the standards may change. We recommend that, the second coat should be applied in a cross coat method.

  6. CLIMATE : The substrate temperature must be above 10 degree C. for better results. But, no coating should be permitted when the substrate is wet from rain or dew when relative humidity is greater 85%. However, this condition will not apply to our PU coatings and they can be applied in any negative environmental conditions, but the substrates should be completely dried.

  7. REPAIRS : If application of the coating is less than 72 hours old, then it may be repaired by applying thinners, like Acetone, MEK for cleaning the coat and then reapply the coating. But, if the coating is 72 hours old and above, then the surface may be cleaned up with the sand paper and then repeat the repair process.

  8. EQUIPMENT CLEAN UP : After coating is used, the equipment must be cleaned up within 30 minutes of final use and it must be cleaned with proper solvents, like MTO, Acetone and MEK, Any materials left in the spray equipment/ brush will solidify and damage the equipment. Special care must be taken with SRL PU coating and the cleaning must be done, as per recommendations. 

  9. VENTILATION : PLEASE MAKE SURE THAT, THE AREA WHERE SRLCOATING IS APPLIED, IS PROPERLY VENTILATED AND NO COATING SHOULD BE DONE IN A CLOSED ROOM WITH NO VENTILATION AND SRL TAKES NO RESPONSIBILITY IF THIS INSTRUCTION IS NOT FOLLOWED.

  10. PRIOR TO COATING : For other safety instruction, please see the product labels.

Contact Us | Disclamair
02 Sreechem Resins Limited
Last modified: January 13, 2003