INSULTOP 'SUPER'
A Polyurethane base for Class Electrical Insulating Varnish for Class-H Insulation,  (Baking Type)

Product Description

Insultop Super is an Insulating impregnation Varnish, based on Polysterene Polyl and Isocyanate base Catalyst. It is very thin in consistency and so, it can poured on the Motors and because of Catalystic reaction, the Varnish sets even at Room Temperature. But, it is advisable to bake it to takeout all the solvents.

Application Areas

Special Motors requires Class-H type of Insulation and temperature Index of 180-200°C. The cured film is resistant to any of oil and also Acid fumes, like H2SO4, HCL etc.

Physical Properties

Colour & Appearance : Light yellow clear liquid.
Solids content (%)
 (1.5 gm./130°C./2 hours)
: 40±1
Viscosity at 23°C. on FC-4 Cup (Secs.) : 30-50
Specific Gravity at 23°C : 0.88±0.02
Flash Point : Above 30°C.
Compatibility with Thinner (%) : More than 300
Recommended Thinner : Insulthin Universal
(SRL Make)
Storage life at room temperature : 12 months.

 

 

 

 

 

 

 

Recommended Curing Schedule      

Time (Hours) : 10 8 6 R. T.
Temperature (Deg. C.) : 150 140 120 72

Curing properties       

Drying in thin layer (1h/150°C) : Sl (Smooth)
Curing in thick layer (4h/100°C+) : Ul (Tack free)
(5h/150°C) : 13.2 (few bubbles)
Tack free time at Room Temperature : 15 minutes
Complete dry : 24 hours
Flexibility (Mandrel Test) : Passes

Typical Properties 

     
Dielectric Strength at Room Temperature (kV/mn) : 105
Dielectric strength after 24 hrs. water immersion at R. T. : 100
Volume resistivity at R. T. (500V DC) Ohm.cm. : 10E15
Volume resistivity after 168h. water immersion at R. T. (Ohm.cm) : 10E14
Dielectric loss factor at R. T. (30V/1kHz) : 0.035
Dielectric loss factor at 155°C : 0.12
Dielectric Constant at R. T. (30 V/1kHz) : 3.5
Dielectric constant at 155°C : 4.0
Tracking Index at 200 V (Drops) : More than 300

Packing

Insultop Super : 500 ml. & 1000 ml.

Safety Measures

Insultop Super  is a flammable liquid. So, dry chemical powder or CO2 or foam is to be used in case of fire and hand-gloves and safety appliances should be used while handling the product. In case of contact, the affected area should be washed with soap and plenty of water.

Contact Us | Disclamair
02 Sreechem Resins Limited